4000 AMP Switchboard (Sparks, USA Parkway)

4000 AMP Switchboard 1 thumbnail4000 AMP Switchboard 2 thumbnail4000 AMP Switchboard 3 thumbnail4000 AMP Switchboard 4 thumbnail4000 AMP Switchboard 5 thumbnail4000 AMP Switchboard 6 thumbnail4000 AMP Switchboard 7 thumbnail
condition: new
engine hours (total):
make / manufacturer: Square D
model name / number: Schneider
size / dimensions: 144" W x 59.5" D x 91.5" H
Product Details:
1-Square D Custom CMM Swbd-QED-2 Switchboard
---------------------------------
Square D Custom CMM Swbd
Designed and Tested in accordance with:
UL 891/NATIONAL ELECTRIC CODE/NEMA PB-2
System Voltage - 480Y/277V 3Ph 4W 60Hz
Source Description - Six Circuit Mains
System Ampacity - 4000A
Bussing - Silver Plated Copper
Neutral Bus - 100%
Max Available Fault Current (RMS) - 65kA
Installed Location: Indoor
Enclosure - Type 3R Non-Walk-in
Accessibility: Front Only
Rodent Barrier
Exterior Paint Color - ANSI 49
Lineup with MasterPact NW Breaker(s)
Ground Lug provided for each device
Copper Ground Bus
Strip Heaters - Internal Power Source with
Thermostat
Seismic Qualified

Dimensions
---------------------------------
1 - 48" Wide Section(s)
1 - 42" Wide Section(s)
1 - 24" Wide Section(s)
1 - 30" Wide Section(s)
4 - 59.5" Deep Enclosure(s)
1 - Dimensions: 144.00" W X 59.5" D X 91.5"H
Approximate Weight: 5131.00 lbs / 2327.42 kgs


Incoming Requirements
---------------------------------
Suitable for Use as Service Entrance When Not
More Than 6 Main Disconnecting Means are
Provided
Entry Point: Left of Lineup, Through the
Bottom
Connection Type: Cable in Bussed Auxiliary
EUSERC Terminals per NV Energy (Northern)
(NV) provided
Incoming Utility Metering Compartment is NOT
provided

Mains
---------------------------------
1 - 4000AF/4000AT 100% 3 Pole Stored Energy,
Fixed Mounted Circuit Breaker, ANSI:
Type NW
Power Trip Unit, Long Time, Short Time,
Instantaneous, Ground Fault
Overcurrent Trip Switch 1A/1B Form C
Contact (SDE)
Auxiliary Switches 4A-4B
Contact Wear Indication - Visual
Energy Reduction Maintenance Switch

Main One
1 - 200A/200A 480V 80% Rated 3 Pole Tenant
Main, EUSERC Meter Socket and Thermal
Magnetic Circuit Breaker: Type JJ

Main Two
1 - 1000AS/1000AT 480V 80% Rated 65 kA 3 Pole
UL, Fixed Mounted Electronic Trip

Circuit Breaker: Type PJ
Ammeter Trip Unit, Long Time, Short Time,
Instantaneous, Ground Fault
Maintenance Mode Switch
Main Three
Hot Sequence Utility: NV Energy
(Northern) (NV)
Standard Door Pattern 1-30in Door, 2
Sockets
Common Main Features:
Padlock Attachment